Monobloc VS-MEG

Home › Products › Monobloc VS-MEG

Monobloc VS-MEG

24 models · integrated Climatix controls
Air conditioning and ventilation

A complete range, controlled and certified

DEPAIR SA has developed a range of 24 air conditioning and ventilation unit models for airflows from 700 to 3,200 m³/h.

These models are fitted with high-efficiency plate heat exchangers (approx. 85%), EC fans and complete controls with data transmission over Modbus TCP or BACnet IP (Climatix as standard). Superior quality components for optimal efficiency and long-term reliability.

Our units are identical to those of the VS-SP range, tested and TÜV-certified to standard EN 1886, rated T2/TB1. Models for higher airflows can be developed on request. Drawings available in REVIT format.

Optional:

Heating and cooling coil management · fire damper management with or without the EasyBus system · K-factor for the fans.

Configuration types

Four layouts: S · H · V · V1

Type S
Type S
Type H
Type H
Type V
Type V
Type V1
Type V1
Technical data

Specifications by airflow

The technical data below is given according to the unit airflow [m³/h].

700 m³/h

MEG700

AirflowMax. external pressure*Motor powerCurrentVoltagePower supply
Supply air700 m³/h780 Pa0.5 kW2.3 A1× 230 V3LNPE 3×16A
Extract air700 m³/h760 Pa0.5 kW2.3 A1× 230 V3LNPE 3×16A

ISO ePM1 60% / F7 filter. *Values at 400 m (ρ = 1.15 kg/m³). Low-voltage conductor cross-sections to be sized in accordance with the local energy supplier’s requirements.

TypeH × W × LengthWeight
MEG 700 S1450 × 735 × 1670 mm240 kg
MEG 700 H1240 × 735 × 2290 mm300 kg
MEG 700 V1500 × 735 × 1700 mm220 kg
MEG 700 V11200 × 735 × 2390 mm340 kg

Options: surface-mounted heating coil · rooftop installation (side inlets and outlets).

1200 m³/h

MEG1200

AirflowMax. external pressure*Motor powerCurrentVoltagePower supply
Supply air1200 m³/h540 Pa0.5 kW2.3 A1× 230 V3LNPE 3×16A
Extract air1200 m³/h510 Pa0.5 kW2.3 A1× 230 V3LNPE 3×16A

ISO ePM1 60% / F7 filter. *Values at 400 m (ρ = 1.15 kg/m³). Low-voltage conductor cross-sections to be sized in accordance with the local energy supplier’s requirements.

TypeH × W × LengthWeight
MEG 1200 S1650 × 735 × 1800 mm280 kg
MEG 1200 H1240 × 735 × 2450 mm330 kg
MEG 1200 V1700 × 735 × 1790 mm240 kg
MEG 1200 V11250 × 735 × 2520 mm420 kg

Options: surface-mounted heating coil · rooftop installation (side inlets and outlets).

1600 m³/h

MEG1600

AirflowMax. external pressure*Motor powerCurrentVoltagePower supply
Supply air1600 m³/h640 Pa0.75 kW3.3 A1× 230 V3LNPE 3×16A
Extract air1600 m³/h610 Pa0.75 kW3.3 A1× 230 V3LNPE 3×16A

ISO ePM1 60% / F7 filter. *Values at 400 m (ρ = 1.15 kg/m³). Low-voltage conductor cross-sections to be sized in accordance with the local energy supplier’s requirements.

TypeH × W × LengthWeight
MEG 1600 S1650 × 935 × 1800 mm320 kg
MEG 1600 H1240 × 935 × 2470 mm350 kg
MEG 1600 V1700 × 935 × 1790 mm280 kg
MEG 1600 V11250 × 935 × 2520 mm420 kg

Options: surface-mounted heating coil · rooftop installation (side inlets and outlets).

2000 m³/h

MEG2000

AirflowMax. external pressure*Motor powerCurrentVoltagePower supply
Supply air2000 m³/h450 Pa0.75 kW3.3 A1× 230 V3LNPE 3×16A
Extract air2000 m³/h430 Pa0.75 kW3.3 A1× 230 V3LNPE 3×16A

ISO ePM1 60% / F7 filter. *Values at 400 m (ρ = 1.15 kg/m³). Low-voltage conductor cross-sections to be sized in accordance with the local energy supplier’s requirements.

TypeH × W × LengthWeight
MEG 2000 S1750 × 935 × 1900 mm350 kg
MEG 2000 H1240 × 935 × 2610 mm370 kg
MEG 2000 V1800 × 935 × 1930 mm310 kg
MEG 2000 V11310 × 935 × 2630 mm440 kg

Options: surface-mounted heating coil · rooftop installation (side inlets and outlets).

2500 m³/h

MEG2500

AirflowMax. external pressure*Motor powerCurrentVoltagePower supply
Supply air2500 m³/h650 Pa1.05 kW1.6 A3× 400 V3LNPE 3×16A
Extract air2500 m³/h620 Pa1.05 kW1.6 A3× 400 V3LNPE 3×16A

ISO ePM1 60% / F7 filter. *Values at 400 m (ρ = 1.15 kg/m³). Low-voltage conductor cross-sections to be sized in accordance with the local energy supplier’s requirements.

TypeH × W × LengthWeight
MEG 2500 S1790 × 1135 × 1900 mm410 kg
MEG 2500 H1330 × 1135 × 2645 mm440 kg
MEG 2500 V1850 × 1135 × 2000 mm360 kg
MEG 2500 V11350 × 1135 × 2770 mm520 kg

Options: surface-mounted heating coil · rooftop installation (side inlets and outlets).

3200 m³/h

MEG3200

AirflowMax. external pressure*Motor powerCurrentVoltagePower supply
Supply air3200 m³/h890 Pa1.8 kW2.8 A3× 400 V3LNPE 3×16A
Extract air3200 m³/h860 Pa1.8 kW2.8 A3× 400 V3LNPE 3×16A

ISO ePM1 60% / F7 filter. *Values at 400 m (ρ = 1.15 kg/m³). Low-voltage conductor cross-sections to be sized in accordance with the local energy supplier’s requirements.

TypeH × W × LengthWeight
MEG 3200 S1870 × 1235 × 1950 mm490 kg
MEG 3200 H1360 × 1235 × 2840 mm540 kg
MEG 3200 V2050 × 1235 × 2100 mm460 kg
MEG 3200 V11450 × 1235 × 2940 mm640 kg

Options: surface-mounted heating coil · rooftop installation (side inlets and outlets).

Downloads

VS-MEG data sheets & drawings

Documents by model and configuration (48 PDFs).

Need a controlled air handling unit?